Wuxi, Jiangsu, China+86 181 1537 2079

WH-RL018 80G Radar Level Transmitter

WH-RL018 80G Radar Level Transmitter:

  • The measurement accuracy of millimeter wave radar can reach +1mm, and the measurement of the blind zone is 50mm.
  • Smaller antenna size to meet more work conditions.
  • A variety of lens antennas, 3 ° emitting angle, more concentrated energy, stronger echo signals, higher reliability compared to other radar gauge under the same industrial and mining conditions.
  • With stronger penetration, it can be used normally in the presence of adhesion and condensation.
  • Dynamic signal range is larger, and the measurement for low permittivity medium is more stable.
  • Multiple measurement mode, the radar response time in the fast measurement mode is less than 1S.

Introduction:

80G radar level transmitter is an advanced level measuring meter, which uses high frequency electromagnetic wave to detect the target. Its high-precision, non-contact measurement method can be widely used in petrochemical industry, storage tank management and other fields.

The gauge has strong penetration ability and extremely narrow beam, can adapt to ultra-complex working conditions. At the same time, it is easy to maintain, simple to operate, with fault alarm and self-diagnosis functions to ensure the normal operation of the instrument.

In addition, the 80G radar level meter can measure almost all media, including liquids, particles, pulp, etc. Its continuous and accurate measurement capability enables it to play an outstanding performance in a variety of applications.

 Applications:

Industry: Steel
Medium: raw coal
Silo diameter: 21 meters
Range: 50m
Industry: Chemical Industry
Medium: stirred reactor
Range: 3m
Application: monitoring water level of river and reservoir
Medium: water
Range: 5m

Parameters:

Measurement Supply2/4 wire system,FMCW  radar
Frequency RangeW-band [76-81GHz]
Max measure range 120 m
 Accuracy±1mm
Output4~20mA,RS-485
 CommunicationHART, MODBUS
 Power supply24 ±6V
Process connectionFlange ≥ DN50, thread ≥G3/4
Process pressure-1...20 bar
Process temperature-40 ~ 200°C
ShellAluminum/stainless steel
 Cable entryM20*1.5
Fault signalConstant current output; 21mA; 3.6mA
Blind zone0.05m /0.2m
Relative humidity<95%
Shock resistancemechanical vibration 10m/s²,(10~150)HZ
Ingress protectionIP67
Explosion-proofExdiall CT6
InstallationThread, Flange